CredoID

Honeywell devices

Configuration of Honeywell devices with CredoID

Honeywell Configuration

In this section will cover how to configure Honeywell devices and use it with CredoID.

Connecting to device

honeywell_login.png

  1. Connect an ethernet cable to the device and enable factory default settings, by turning DIP switch 2 to ON. This will enable factory default communication parameters.

    • Network: Static IP address: 192.168.0.251
    • Subnet Mask: 255.255.0.0
    • Default Gateway: 192.168.0.1
    • DNS Server: 192.168.0.1

Creating a web user

Create an optional web interface user if you want to change device settings later.

honeywell_create_user.png

  1. Navigate to "Users" tab.

  2. Click "New User" button.

    • Username: type name for user, don't use 'admin'
    • Password: create strong password for the user
  3. Click "Save" button.

Configuring Network settings

honeywell_network.png

  1. Navigate to "Network" tab.

In the IP Settings section, configure the following:

  1. Click "Accept".

Ensure the device is on the same subnet as the system running the CredoID service.

Setting host communication

honeywell_hostcom.png

  1. Navigate to "Host Comm" tab.

    • Connection Type: IP Client.
    • Data Security: TLS if Available.
    • Host IP: Enter IP address where CredoID is running.
    • Connection Mode: Continuous.
    • Port Number: 3001.
  2. Click "Accept".

Applying configuration

  1. Set all DIP switches to OFF position.
  2. Click "Apply Settings" on the left menu. Device will reboot.

Now you can add device in CredoID which will appear in "Discover" list.

Make sure there is an incoming connection exception in your firewall settings for port 3001.

Honeywell With CredoID

This section explains how to setup device with CredoID.

Adding device from "Discover" list

If device configured correctly in previous section, it should appear in the "Discover" list.

  1. Navigate to "Hardware" -> "Devices" tab.

devices1.png

  1. Click "Discover" button.

honeywell_discovery.png

  1. Select device from the list and click "Select":

honeywell_general.png

  1. Click "Save" button.
    After saving the device, if device status should change to "Online" after few moments.
  2. Click Synchronize button and wait until device Configuration state is "Completed"

Adding device modules

This section contains information about Honeywell device modules configuration.

  1. Navigate to "Hardware" -> "Devices" tab and click on configured device.
  2. Click on "Devices Modules" tab.

honeywell_modules.png

  1. Click "Discover" button to detect modules automatically or click "Add" button to add modules manually.
  2. Click "Save" button.

It is recommended to always add modules by using "Discover" button.

Some devices do not have a dedicated RS485 port but can use 1st Reader Port for RS485 communication if it is enabled in the device settings.
Readers will not function on 1st port if the controller is configured to use that port for RS485 communication.
rs485_enable_merc.png