This feature allows to generate basic time and attendance reports. Before using this feature, at least 2 readers must be configured with Clock in and Clock out functions.

Operator required to have "events.read", "doors.read", "reports.read", "users.read", "filter.write" permissions in order to generate T&A report.


  • Select Clock-In readers - select reader, which will be used for entry time calculation. Reader must have "Time and attendance" - "Clock In" parameter selected Door configuration.
  • Select Clock-In readers - select reader, which will be used for entry time calculation. Reader must have "Time and attendance" - "Clock Out" parameter selected at Door configuration.
  • From/To - selected interval will be used for report generation.
  • Select users - select specific users from the list, who will appear in generated report.
  • Select Companies/Departments/Titles - if field is selected, only those users with selected company/department/title will appear in generated list.

Mismatching values will appear with 0 total time value in report. Example: if "Midpoint Security" company filter is applied to the filter, and single user is selected from other company, that user will have total value of 0 hours.

  • First In - Last out - if checked, total time will be calculated between the first clock in access event and the last clock out access event - all access events during the day are ignored.
    If unchecked, total time will be calculated with intervals -  first clock in - first clock, after this interval again first clock in - first clock out. Sum of all of these interval will be shown in "Working hours"

At the table:

  • In - First clock in of the day.
  • Out - last clock out time of the day

No exit time/No entry time means that the is no valid Clock in - Clock out interval during the day.